@article {1498263, title = {Surgical Confusions in Ophthalmology: Description, Analysis, and Prevention of Errors from 2006 through 2017}, journal = {Ophthalmology}, volume = {127}, number = {3}, year = {2020}, month = {2020 Mar}, pages = {296-302}, abstract = {PURPOSE: To characterize surgical confusions in ophthalmology to determine their incidence, root causes, and impact on patients and physicians. DESIGN: Retrospective cohort study of errors in ophthalmic surgical procedures between January 1, 2006, and December 31,\ 2017. PARTICIPANTS: One hundred forty-three cases involving surgical confusions. METHODS: Cases were identified by the Ophthalmic Mutual Insurance Company from closed case files and by the New York State Health Department from the New York Patient Occurrence Reporting and Tracking program that identified the surgical confusions. MAIN OUTCOME MEASURES: Incidence and impact by intended surgery, error type, and root cause as well as preventability by the Universal Protocol. RESULTS: Of the 143 cases of surgical confusions identified, 92 cases (64.3\%) were deemed preventable by the Universal Protocol. Approximately two thirds, 95 cases (66.4\%), were cases of incorrect implants being used during cataract surgery (cataract extraction and intraocular lens implantation), of which 33 cases (34.7\%) were not preventable by the Universal Protocol. Wrong eye blocks or anesthesia accounted for 20 cases (14.0\%), incorrect eye procedures accounted for 10 cases (7.00\%), incorrect refractive surgery measurements accounted for 6 cases (4.20\%), incorrect patient or procedure accounted for 5 cases (3.50\%), incorrect intraocular gas concentration accounted for 4 cases (2.80\%), and incorrect medication in surgery accounted for 3 cases (2.10\%). The most common root cause of confusion was an inadequately performed time out, which was responsible for nearly one third of all surgical confusions, 46 cases (32.2\%). Incorrect lens orders or calculations before surgery (so-called upstream errors) were the second most common cause of surgical confusion, involving 31 cases (21.7\%). The average legal indemnity for incorrect implant during cataract surgery was $57 514 (United States dollars). The average indemnity for incorrect refractive surgery measurement was $123 125, that for incorrect eye procedure was $50 000, and that for incorrect gas concentration was $220 844. CONCLUSIONS: Most surgical confusions could have been prevented by following the Universal Protocol properly. However, upstream errors, originating in the clinic or office before surgery, and ineffective communication during time outs suggest a need for modification of the Universal Protocol.}, issn = {1549-4713}, doi = {10.1016/j.ophtha.2019.07.013}, author = {Parikh, Ravi and Palmer, Valerie and Kumar, Aman and Simon, John W} }