January 2014

Cruz NM, Yuan Y, Leehy BD, Baid R, Kompella U, Deangelis MM, Escher P, Haider NB. Modifier genes as therapeutics: the nuclear hormone receptor Rev Erb alpha (Nr1d1) rescues Nr2e3 associated retinal disease. PLoS One 2014;9(1):e87942.Abstract
Nuclear hormone receptors play a major role in many important biological processes. Most nuclear hormone receptors are ubiquitously expressed and regulate processes such as metabolism, circadian function, and development. They function in these processes to maintain homeostasis through modulation of transcriptional gene networks. In this study we evaluate the effectiveness of a nuclear hormone receptor gene to modulate retinal degeneration and restore the integrity of the retina. Currently, there are no effective treatment options for retinal degenerative diseases leading to progressive and irreversible blindness. In this study we demonstrate that the nuclear hormone receptor gene Nr1d1 (Rev-Erbα) rescues Nr2e3-associated retinal degeneration in the rd7 mouse, which lacks a functional Nr2e3 gene. Mutations in human NR2E3 are associated with several retinal degenerations including enhanced S cone syndrome and retinitis pigmentosa. The rd7 mouse, lacking Nr2e3, exhibits an increase in S cones and slow, progressive retinal degeneration. A traditional genetic mapping approach previously identified candidate modifier loci. Here, we demonstrate that in vivo delivery of the candidate modifier gene, Nr1d1 rescues Nr2e3 associated retinal degeneration. We observed clinical, histological, functional, and molecular restoration of the rd7 retina. Furthermore, we demonstrate that the mechanism of rescue at the molecular and functional level is through the re-regulation of key genes within the Nr2e3-directed transcriptional network. Together, these findings reveal the potency of nuclear receptors as modulators of disease and specifically of NR1D1 as a novel therapeutic for retinal degenerations.
Amparo F, Jin Y, Hamrah P, Schaumberg DA, Dana R. What is the value of incorporating tear osmolarity measurement in assessing patient response to therapy in dry eye disease?. Am J Ophthalmol 2014;157(1):69-77.e2.Abstract
PURPOSE: To evaluate the correlation between changes in tear osmolarity, symptoms, and corneal fluorescein staining in patients with dry eye disease (DED). DESIGN: Retrospective, clinic-based cohort study. METHODS: In this single-institution study, we reviewed the charts of 186 patients with DED from whom we had data on tear osmolarity, symptoms, and corneal fluorescein staining from 2 separate visits. Main outcomes included the correlation of the changes between the 2 visits for tear osmolarity (TearLab system), symptoms (Ocular Surface Disease Index), and corneal fluorescein staining (modified Oxford scheme). For tear osmolarity and corneal fluorescein staining the scores from the eye with highest readings were analyzed. The correlations were repeated on subgroups based on proposed cutoffs for DED severity and on patients' treatment. RESULTS: We found a modest, though statistically significant, correlation between changes in corneal fluorescein staining and symptoms of DED (R = 0.31; P < .001). However, there was no correlation between the recorded change in tear osmolarity and symptoms (R = -0.091; P = .38) or between changes in tear osmolarity and corneal fluorescein staining (R = -0.02; P = .80). This lack of correlation was consistent in all the subgroups studied. A multivariate analysis revealed that changes in corneal fluorescein staining had predictive value on symptom changes, whereas tear osmolarity changes did not. CONCLUSIONS: Changes in tear osmolarity do not correlate significantly with changes in patient symptoms or corneal fluorescein staining in dry eye disease.
Borodic GE, Caruso P, Acquadro M, Chick S. Parry-Romberg syndrome vasculopathy and its treatment with botulinum toxin. Ophthalmic Plast Reconstr Surg 2014;30(1):e22-5.Abstract
Parry-Romberg syndrome is a rare condition characterized by progressive, hemifacial atrophy, hair loss, enophthalmos, retinal vasculopathy occasionally associated with hemicranial pain syndrome (secondary trigeminal neuralgia). The cause of the condition is unknown; however, substantial evidence suggests that vasculopathy plays a significant role in the genesis of the neurologic damage and facial lipodystrophy. Herein describes a case of Parry-Romberg syndrome treated with repetitive botulinum type A toxin injections, with almost complete resolution of severe chronic pain.
Ciolino JB, Stefanescu CF, Ross AE, Salvador-Culla B, Cortez P, Ford EM, Wymbs KA, Sprague SL, Mascoop DR, Rudina SS, Trauger SA, Cade F, Kohane DS. In vivo performance of a drug-eluting contact lens to treat glaucoma for a month. Biomaterials 2014;35(1):432-9.Abstract
For nearly half a century, contact lenses have been proposed as a means of ocular drug delivery, but achieving controlled drug release has been a significant challenge. We have developed a drug-eluting contact lens designed for prolonged delivery of latanoprost for the treatment of glaucoma, the leading cause of irreversible blindness worldwide. Latanoprost-eluting contact lenses were created by encapsulating latanoprost-poly(lactic-co-glycolic acid) films in methafilcon by ultraviolet light polymerization. In vitro and in vivo studies showed an early burst of drug release followed by sustained release for one month. Contact lenses containing thicker drug-polymer films demonstrated released a greater amount of drug after the initial burst. In vivo, single contact lenses were able to achieve, for at least one month, latanoprost concentrations in the aqueous humor that were comparable to those achieved with topical latanoprost solution, the current first-line treatment for glaucoma. The lenses appeared safe in cell culture and animal studies. This contact lens design can potentially be used as a treatment for glaucoma and as a platform for other ocular drug delivery applications.
Alberti CF, Peli E, Bowers AR. Driving with hemianopia: III. Detection of stationary and approaching pedestrians in a simulator. Invest Ophthalmol Vis Sci 2014;55(1):368-74.Abstract
PURPOSE: To compare blind-side detection performance of drivers with homonymous hemianopia (HH) for stationary and approaching pedestrians, initially appearing at small (4°) or large (14°) eccentricities in a driving simulator. While the stationary pedestrians did not represent an imminent threat, as their eccentricity increased rapidly as the vehicle advanced, the approaching pedestrians maintained a collision course with approximately constant eccentricity, walking or running, toward the travel lane as if to cross. METHODS: Twelve participants with complete HH and without spatial neglect pressed the horn whenever they detected a pedestrian while driving along predetermined routes in two driving simulator sessions. Miss rates and reaction times were analyzed for 52 stationary and 52 approaching pedestrians. RESULTS: Miss rates were higher and reaction times longer on the blind than the seeing side (P < 0.01). On the blind side, miss rates were lower for approaching than stationary pedestrians (16% vs. 29%, P = 0.01), especially at larger eccentricities (20% vs. 54%, P = 0.005), but reaction times for approaching pedestrians were longer (1.72 vs. 1.41 seconds; P = 0.03). Overall, the proportion of potential blind-side collisions (missed and late responses) was not different for the two paradigms (41% vs. 35%, P = 0.48), and significantly higher than for the seeing side (3%, P = 0.002). CONCLUSIONS: In a realistic pedestrian detection task, drivers with HH exhibited significant blind-side detection deficits. Even when approaching pedestrians were detected, responses were often too late to avoid a potential collision.
Andreoli MT, Yiu G, Hart L, Andreoli CM. B-scan ultrasonography following open globe repair. Eye (Lond) 2014;28(4):381-5.Abstract
PURPOSE: To examine the accuracy and predictive ability of B-scan ultrasonography in the post-repair assessment of an open globe injury. METHODS: In all, 965 open globe injuries treated at the Massachusetts Eye and Ear Infirmary between 1 January 2000 and 1 June 2010 were retrospectively reviewed. A total of 427 ultrasound reports on 210 patients were analyzed. Ultrasound reports were examined for the following characteristics: vitreous hemorrhage, vitreous tag, retinal tear, RD (including subcategories total RD, partial RD, closed funnel RD, open funnel RD, and chronic RD), vitreous traction, vitreous debris, serous choroidal detachment, hemorrhagic choroidal detachment, kissing choroidal detachment, dislocated crystalline lens, dislocated intraocular lens (IOL), disrupted crystalline lens, intraocular foreign body (IOFB), intraocular air, irregular posterior globe contour, disorganized posterior intraocular contents, posterior vitreous detachment, choroidal vs retinal detachment, vitreal membranes, and choroidal thickening. The main outcome measure was visual outcome at final follow-up. RESULTS: Among 427 B-scan reports, there were a total of 57 retinal detachments, 19 retinal tears, 18 vitreous traction, 59 serous choroidal detachments, 47 hemorrhagic choroidal detachments, and 10 kissing choroidal detachments. Of patients with multiple studies, 26% developed retinal detachments or retinal tears on subsequent scans. Ultrasound had 100% positive predictive value for diagnosing retinal detachment and IOFB. The diagnoses of retinal detachment, disorganized posterior contents, hemorrhagic choroidal detachment, kissing choroidal detachment, and irregular posterior contour were associated with worse visual acuity at final follow-up. Disorganized posterior contents correlated with particularly poor outcomes. CONCLUSIONS: B-scan ultrasonography is a proven, cost-effective imaging modality in the management of an open globe injury. This tool can offer both diagnostic and prognostic information, useful for both surgical planning and further medical management.
Chen Y, Chauhan SK, Lee SH, Saban DR, Dana R. Chronic dry eye disease is principally mediated by effector memory Th17 cells. Mucosal Immunol 2014;7(1):38-45.Abstract
Recent experimental and clinical data suggest that there is a link between dry eye disease (DED) and T-cell-mediated immunity. However, whether these immune responses are a consequence or cause of ocular surface inflammation remains to be determined. Thus far, only models of acute DED have been used to derive experimental data. This is in contrast to clinical DED which usually presents as a chronic disease. In the present study, using a murine model of chronic DED, it was established that the chronic phase of the disease is accompanied by T helper type 17 (Th17) responses at the ocular surface and that a significant memory T-cell population can be recovered from chronic DED. This memory response is predominantly mediated by Th17 cells. Moreover, adoptive transfer of this memory T-cell population was shown to induce more severe and rapidly progressing DED than did the adoptive transfer of its effector or naive counterparts. Not only do these results clearly demonstrate that effector memory Th17 cells are primarily responsible for maintaining the chronic and relapsing course of DED, but they also highlight a potentially novel therapeutic strategy for targeting memory immune responses in patients with DED.

Pages