An open-source computational tool to automatically quantify immunolabeled retinal ganglion cells.

Citation:

Dordea AC, Bray M-A, Allen K, Logan DJ, Fei F, Malhotra R, Gregory MS, Carpenter AE, Buys ES. An open-source computational tool to automatically quantify immunolabeled retinal ganglion cells. Exp Eye Res 2016;147:50-6.

Date Published:

2016 Jun

Abstract:

A fully automated and robust method was developed to quantify β-III-tubulin-stained retinal ganglion cells, combining computational recognition of individual cells by CellProfiler and a machine-learning tool to teach phenotypic classification of the retinal ganglion cells by CellProfiler Analyst. In animal models of glaucoma, quantification of immunolabeled retinal ganglion cells is currently performed manually and remains time-consuming. Using this automated method, quantifications of retinal ganglion cell images were accelerated tenfold: 1800 images were counted in 3 h using our automated method, while manual counting of the same images took 72 h. This new method was validated in an established murine model of microbead-induced optic neuropathy. The use of the publicly available software and the method's user-friendly design allows this technique to be easily implemented in any laboratory.

See also: Glaucoma, June 2016, All, 2016
Last updated on 06/24/2016