Incidental finding of a retained intracorneal wooden foreign body

Citation:

Zidan A, Barbosa J, Diskin J, McDermott M. Incidental finding of a retained intracorneal wooden foreign body. BMJ Case Rep 2023;16(12)

Date Published:

2023 Dec 11

Abstract:

We present a case of an intracorneal wooden foreign body that remained undetected for 15 years following an ocular injury sustained during gardening. The patient presented with stable visual acuity despite the long-standing presence of a wooden splinter embedded in the cornea. Interestingly, Pentacam corneal tomography did not show any abnormalities despite the foreign body piercing through the corneal stroma and endothelium. This case may serve as an opportunity to re-examine the approach to managing chronic and stable intracorneal wooden foreign bodies and explore the implications of continued observation rather than surgical management.

Last updated on 01/03/2024